Commercial Structured Cabling for Data Centers & Offices
From Cat5e in existing offices to Cat8 in the server room, plus single-mode and multimode fiber, racks, ladder rack, labeling and tested links for data centers, new build-outs, tenant improvements and existing offices. Commercial only, no residential.
- Commercial only
- Cat5e–Cat8 · Fiber
- Tested & labeled
Who we cable for
From a single added drop to a full building, we plan the pathways, closets and labeling so the network is easy to run for years.
Data centers & server rooms
Racks and cabinets, high-density copper and fiber — including Cat8 for short 25/40 Gb links — overhead ladder rack, clean patching and documentation built for serviceability.
New office build-outs
We work with your GC during construction to plan drops, MDF/IDF closets, Wi-Fi locations and pathways, ready on move-in day.
Existing offices
Add drops, relocate desks, replace failing runs and clean up closets with minimal disruption, including after hours.
Tenant improvements
Suite remodels and expansions: demo of abandoned cable, new runs, closet updates and re-patching.
Structured cabling services
Everything between your internet handoff and the jack on the wall, installed neatly and documented.
Horizontal & backbone copper
Cat5e through Cat8 from the closet to every desk, AP, camera and printer, plus copper tie cables between closets. Most new office work is Cat6 or Cat6A; Cat8 is reserved for short data-center links.
Fiber optic backbone
Single-mode (OS2) and multimode (OM3/OM4) fiber between floors, closets and buildings, terminated in rack-mount enclosures.
Data center cabling
High-density copper — including Cat8 for short 25/40 Gb server-room links — and fiber, pre-terminated trunks where they make sense, neat overhead pathways and airflow-aware layouts.
MDF / IDF & rack builds
Two-post racks, four-post frames, enclosed and wall-mount cabinets, backboards, power, UPS and grounding.
Cable ladder & tray
Overhead ladder rack in closets, basket tray down corridors, J-hook pathways and proper supports.
Patch panels & cable management
Patch panels, horizontal and vertical managers, color-coded patch cords and hook-and-loop. No crushed zip ties.
Labeling & documentation
Every cable labeled at both ends, panel schedules and as-built floor plans, so your IT team knows exactly what goes where.
Testing & certification
Copper permanent-link testing and fiber loss testing, with reports delivered at closeout.
Moves, adds & changes
New drops, relocated desks, added APs and cameras, and closet re-patching for growing offices.
Legacy cable cleanup
Removal of abandoned cable and rebuilding of tangled closets into clean, labeled racks.
Grounding & bonding
Telecom grounding busbars and rack bonding for safe, stable equipment rooms.
Pathways & firestop
Sleeves, conduit, low-voltage brackets and fire-rated pathway devices at rated walls.
How a C13 cabling project works
A simple, predictable process with no surprises at closeout.
Site walk
We walk the space, check ceilings, pathways and closets, and confirm drop counts with you.
Design & quote
Drop map, closet and rack layout, cable type per location, and a clear written quote.
Install
Pathways first, then pulls, with proper support, bend radius and separation from power.
Terminate & dress
Jacks and panels terminated, cables dressed into managers, everything labeled.
Test & certify
Every link tested; certification reports on request.
Document & hand off
Panel schedules and as-builts delivered so your IT team can manage it.
Copper cable categories we install
From existing Cat5e in older offices to Cat8 in the server room. We are not limited to Cat6 and Cat6A.
| Category | Max speed | Bandwidth | Max distance | Best for |
|---|---|---|---|---|
| Cat5e | 1 Gb (up to 2.5 Gb on a good link) | 100 MHz | 100 m | Existing wiring in older buildings; still fine for gigabit when it tests good |
| Cat6 | 1 Gb at 100 m; 10 Gb only on short runs | 250 MHz | 100 m (about 37–55 m for 10 Gb) | Desks, phones, printers and many offices |
| Cat6A | 10 Gb | 500 MHz | 100 m | Most new offices, Wi-Fi access points and long-life buildings |
| Cat7 / Cat7A | 10 Gb | 600 MHz / 1 GHz | 100 m | ISO/IEC systems (mostly Europe). Not a TIA category; true links use GG45 or TERA, not RJ45 |
| Cat8 | 25 / 40 Gb | 2,000 MHz | 30 m | Short, shielded data-center and server-room links (not office horizontal cabling) |
Speeds and distances follow ANSI/TIA and IEEE application limits (and ISO/IEC for Cat7/7A). A link performs only as well as its lowest-rated part, so the cable, jacks, panels and patch cords all need to match. “Cat6A+” and “Cat6e” are marketing names, not official categories — for 10 Gb to 100 m, specify true Cat6A. Cat8 (TIA) and ISO Cat8.1 use a shielded RJ45 jack; ISO also defines Cat8.2 with non-RJ45 connectors. Cat8 is limited to 30 m (typically 24 m of cable plus short patch cords) and at most two connectors. Sources: Intel Ethernet cable guide, Telegärtner Category 8 fact sheet.
Which do I need?
- Cat6A is what we recommend for most new offices: 10 Gb to every jack at the full 100 m distance, and it handles high-power PoE for Wi-Fi and cameras well.
- Cat6 is a solid, lower-cost choice for desks and phones when 10 Gb over long runs isn't required.
- Cat8 is for short data-center or server-room links — up to 30 m — that need 25 or 40 Gb Ethernet. It is not a replacement for everyday office cabling.
- If your building already has Cat5e, we can test it and reuse what still meets the need.
- Many projects mix categories. We'll recommend the right cable for each location. For a deeper comparison, see Cat6 vs. Cat6A vs. Cat8.
Done right, built to last
- Pathways supported every few feet, never laid on ceiling tiles
- Bend radius and pull tension kept within manufacturer limits
- Separation from electrical and lighting
- Hook-and-loop instead of over-tightened zip ties
- Plenum-rated cable where the space requires it
- Firestopping at rated wall penetrations
- Labels at both ends that match the panel and floor plan
Planning cloud phones too?
Phones, Wi-Fi and cameras depend on good cabling and PoE switching. Because C13 does both, your cloud phone rollout and cabling happen on one schedule, with one team accountable.
Commercial cabling FAQ
Do you do residential cabling?
No. C13 is a commercial-only contractor. We cable offices, data centers, warehouses, retail, medical and other commercial spaces, not homes.
Which cable category should we install?
For most new offices, Cat6A is the best all-around choice: 10 Gb Ethernet over the full 100 m channel, with better heat handling in large PoE bundles for Wi-Fi 6/6E/7 access points and cameras. Cat6 is still a solid, lower-cost option for desks, phones and printers when you don't need 10 Gb at full distance. Cat8 is for short data-center or server-room links (up to 30 m) that need 25 or 40 Gb. If the building already has Cat5e, we can test it — many runs will still do gigabit just fine. We'll recommend the right mix for each location.
Do you install Cat7, Cat8 or “Cat6A+”?
Yes, we install the category that fits the job, including Cat8 for short 25/40 Gb data-center links. A few naming caveats: “Cat6A+” and “Cat6e” are marketing names, not official TIA or ISO categories — for 10 Gb to 100 m, specify true Cat6A. Cat7 and Cat7A are ISO/IEC standards (Class F and FA), not TIA standards, which is what most U.S. commercial work is certified to. True Cat7/7A uses specialized connectors (GG45 or TERA), not the familiar RJ45 jack, so many “Cat7” cables sold with RJ45 plugs can't be certified as a Cat7 channel. We'll steer you to a standard we can test and document.
Can you work with existing Cat5e?
Yes. Cat5e is still a recognized TIA category and supports gigabit Ethernet (and often 2.5 Gb) to 100 m when the installed link tests good. We test what's already in the walls, reuse what meets the need, and replace or add only what's required.
What does plenum (CMP) mean?
Plenum-rated cable has a jacket designed for air-handling spaces, such as many drop ceilings used as return-air plenums. Code and the building determine where it's required; we check before quoting.
Can you cable an office that's already occupied?
Yes. We add drops, relocate workstations, re-cable failing runs and clean up closets in working offices, and can schedule after hours to avoid disrupting your staff. After-hours labor is billed at 1.5x our standard hourly rate; holiday and emergency work is billed at 2x.
Is every cable tested?
Every run is terminated, labeled and tested. Full certification reports (permanent-link testing with a certification tester) are available and recommended for new installs and data centers.
What about old abandoned cable?
Abandoned cable adds fire load and clutter. We can identify and remove legacy cabling as part of a project or on its own.
Do you work with general contractors?
Yes. For new office build-outs and tenant improvements we coordinate with your GC, electrician and IT team on pathways, closet locations and the schedule.
Guides: Cat6 vs. Cat6A vs. Cat8 · Network rack cleanup · PoE for phones, cameras and Wi-Fi · Fiber vs. copper · Office move checklist
Related services: Fiber optic cabling · MDF / IDF closets · Business Wi-Fi
Serving commercial clients across the Phoenix metro:
